Abstract
In 1999, the first practical non-contact and non-restrictive (NCNR) Area/Velocity flow meter that was suitable to measure flow in sewers was introduced. This meter utilizes an ultrasonic transducer to measure depth and digital Doppler radar to measure velocity. The sensor is mounted above and out of the flowing liquid eliminating the need for site visits for unplanned maintenance due to sensor fouling.
Advantages of these meters include a drastic reduction in confined space entry as well as a wireless communication feature that eliminates costly site visits to collect flow data. The accuracy, reliability, and non-contact nature of these meters makes it possible to offer a totally hands-off approach to flow monitoring allowing municipalities to pay only for the flow data they need without the capital expense of flow meter purchase through a rapidly growing trend in the market called Data Delivery Service (DDS).
The accuracy of these meters in low flow depths up to surcharge conditions has been independently verified many times over the years including both laboratory and field evaluations. This paper will discuss the results of these independent verifications, as well as practical applications and the stability of the data collection model.
Key Words
Flow Monitoring, Wastewater, Verification, Stability, Technology, Maintenance, Non-Contact
Introduction
Flow Measurement Methods – Level
Weirs were used to regulate flow through Roman aqueducts. More recently, flumes have become popular for measuring flow in sewers. Both flumes and weirs introduce some restriction to flow causing the level at points in the flow path to rise as a function of flow rate. Documenting this level to flow relationship in a weir or flume establishes what is called a primary flow element. Flow rate can now be derived from a simple level measurement at a particular point in the flow element. Flumes have smooth and gradual restrictions that do not collect debris making them ideal choices for measuring dirty flows such as mining slurries and sewage. Originally, level measurements were made with a simple ruler and then evolved into a float and ruler. In the second half of the 20th Century, submerged pressure devices became the standard for measuring level (depth). Many modern flumes and weirs now incorporate ultrasonic non-contact level sensors. Noncontact flow monitoring is the preferred technology because of its reliability and relatively low maintenance.
Robert Manning introduced what is now called the Manning Equation in December 1889. This empirical formula has found widespread use calculating open channel gravity flow in both natural and engineered channels. Simply put, the formula uses depth, channel slope, and roughness to infer flow rate. Even though the Manning Equation does not directly measure flow rate, an instrument implementing the formula and a means for measuring level became popular in the 1960’s. A major improvement occurred when non-contact level sensors became available. These sensors combined with the Manning Equation established the first non-contact and non-restrictive means for deducing flow rate and significantly increased the popularity of this method. The method maintained popularity until the advent of Area/Velocity (AV) flow meters introduced in the late 1970’s.
Limitations of Flow Calculations based on Level
Flumes and weirs introduce restrictions to flow and only measure accurately over a relatively narrow range of flow rates. This means that they must be sized correctly for the application and are prone to errors if normal flows increase over time or if flow increases significantly during storm events due to Inflow and Infiltration (I&I). Construction and installation cost for larger line sizes is not insignificant. An instrument using the Manning Equation does not restrict flow but relies on correct inputs for slope and roughness. As errors in estimating these variables are easy to make and can cause large fluctuations in the inferred flow rate, Manning’s equation is not typically used as the primary means for determining flow rate but instead has found a place as a rough quality check on other flow data.
Flow Measurement Methods – Area/Velocity (A/V)
A significant breakthrough occurred with the introduction of A/V flow meters. For the first time there was a flow meter that measured both level and velocity. The addition of velocity allowed these flow meters to implement the Continuity Equation, Q = (Vm) (A) to calculate flow rate (see Figure 1). A/V flow meters using the Continuity Equation have important advantages over level only devices. The Continuity Equation fundamentally differs from the Manning Equation in that velocity is measured directly rather than inferring a velocity from slope and roughness. Difficult estimates of pipe slope and roughness are eliminated. A/V flow meters measure accurately over a wide range of flow rates and are not limited to the narrow range of level only meters. Downstream restrictions can cause huge errors when level only devices are used. If the flow became blocked, the pipe level could be at a maximum (full pipe) with the velocity and flow rate at zero. A level only meter would register the maximum flow rate it was scaled for. In this same example, a flow meter using the Continuity Equation correctly outputs a zero flow rate by multiplying the area of the full pipe A=100%) by a velocity of zero.

Non-Contact Velocity Sensing
Similar to the major improvement that occurred when ultrasonic sensors became available for monitoring level, cost reductions brought about by the commercialization of radar for applications such as police speed guns made radar velocity sensing affordable and noncontact A/V flow meters possible.
FLO-DAR was first introduced in 1999 and provided yet another breakthrough in that the flow meter brought together ultrasonic level, radar surface velocity and combined those two measurements with a novel mathematical model to translate surface velocity to mean velocity – finally making an accurate non-contact A/V flow meter. FLO-DAR is the first practical flow meter in use today that has all the advantages of the preceding technologies with none of their disadvantages. It was not the first non-contact and non-restrictive (NCNR) flow meter as there are other techniques such as laser velocimetry; however, FLO-DAR is the first practical NCNR device suited to measure flow in sewers.
FLO-DAR uses an ultrasonic transducer to measure depth and digital Doppler radar to measure velocity from a sensor that is mounted above and out of the flowing liquid. The level transducer produces acoustic pulses and measures the time required for each pulse to reach, reflect off of the water surface and return to the transducer. The sensor’s microprocessor uses the speed of sound in air, adjusted for the local temperature, to calculate the distance that the water surface is from the FLO-DAR sensor. During installation the elevation of the sensor is recorded in the site setup information and is used to convert this distance into depth. The standard level transducer operates at 83 kHz and measures distance up to 60″ (1.5m). The long-range transducer operates at 47 kHz and measures distance up to 20′ (7.9m). Acoustic time of travel is a widely accepted method for accurate, stable and non-contact level measurement.
Digital Doppler Radar
Digital Doppler radar technology is similar to what is used to create radar images in weather reports and for law enforcement to monitor the speed of traffic. FLO-DAR uses radar to measure the surface velocity of the flow being measured. Ripples, bubbles or other features on the surface reflect the transmitted radar energy back to the radar horn where the returned frequency is compared to the original transmitted frequency. The difference between these frequencies is called the Doppler frequency and is directly proportional to the velocity of the reflectors or the surface velocity of the flow. Over a period of time the various Doppler frequencies or velocity returns are sorted through a process called a fast Fourier transform (FFT). After the sorting, a large buildup in amplitude occurs corresponding to the surface velocity of the flow. This can be seen in a graph of the FFT (see Figure 2). Extensive mathematical computations are required to accomplish the FFTs in a timely fashion. This processing power is provided by an embedded digital signal processor (DSP).

Doppler shift is a physical phenomenon directly related to the radiated frequency (24GHz for FLO-DAR) and the velocity of the object the energy is reflecting back from, in this case the water surface. This makes the velocity calibration of FLO-DAR directly equivalent to the accuracy and stability of the radar frequency. FLO-DAR’s radar system meets Federal Communications Commission (FCC) and other worldwide agencies stringent licensing requirements that include maintaining operation within ultra-tight frequency and stability limits. This means calibration of surface velocity is within ±0.5% and periodic calibration is not required. FLO-DAR uses the Continuity Equation to calculate flow rate.
Surface Velocity to Mean Velocity Conversion
Following the Continuity Equation, Q = (Vm)(A), mean velocity is required to accurately calculate flow rate. It is important to distinguish the difference between surface velocity and mean velocity, as surface velocity will differ from mean velocity by up to 15% in ideal conditions, and diverge even further when conditions are less than ideal. Fortunately, mean velocity can be accurately calculated once surface velocity and level are known. For gravity flow in a pipe, a natural relationship will develop between any particle in the flow with every other particle. This is called developed flow. Finite element modeling was used to determine the relationship of the velocity at the surface to the mean velocity. This relationship varies with level. Additional work was done to fine tune the model for variations in pipe size. Data from this mathematical model was used to create a surface to mean velocity algorithm that was incorporated into FLO-DAR’s flow equations (see Figure 3). FLO-DAR was then tested at laboratories and calibrated field sites. The laboratory and field test results confirmed the validity of the algorithm.

Surcharge
One limitation of these non-contact sensors is that they may be negatively affected when submerged. During surcharge conditions the FLO-DAR sensor is often submerged to a point where the radar and ultrasonic transducers are inoperable. An alternate flow monitoring method is required to maintain accurate measurement during surcharge. Every FLO-DAR sensor has a built-in pressure transducer that measures surcharge level during these conditions. This information may be important for operators and planners to evaluate future changes in their distribution system. A surcharge velocity option is available for applications requiring seamless flow data both in normal and surcharge conditions. The surcharge velocity sensor (SVS) attaches to the bottom of the FLO-DAR sensor and begins to measure velocity when the depth is within 2 to 3 inches below the crown of the pipe and continues to measure velocity until the surcharge recedes. During surcharge, the flow area calculation assumes a full pipe and the SVS velocity is used in lieu of radar velocity to calculate flow rate. The surcharge velocity sensor is a streamlined electromagnetic type sensor that can measure very low velocities as well as reverse surcharge velocities (see Figure 4).

System Accuracy
FLO-DAR accuracy from low flow depths up to surcharge conditions has been independently verified many times over the years including a formal evaluation (Tests of Open Channel Flow Meters in 36″ Pipe by Alden Research Laboratory, Inc.) and field evaluations such as the one completed for the East Bay Municipal Utility District by V&A Engineering (EBMUD Flow Monitoring Technologies Evaluation Study). The average error in the Alden evaluation was 1.9% with a maximum error of 3.4% (see Figure 5). The EBMUD technology evaluation found FLO-DAR velocity to be within 1.4% of the velocity profile data used as a standard (see Figure 6). FLO-DAR was deemed usable in 87% of their study locations, a higher percentage than any other technology. Recently CH2M HILL was commissioned to verify the calibration of 15 Hach Data Delivery Services (DDS) FLO-DAR installations located in Lawrence, Kansas. These meters have been installed for over three years continuously sending flow data via cellular modem and the internet to city managers and engineers. The average error reported by CH2M HILL was under ±5%. The majority of the FLO-DAR velocity errors were ±3.5% or less after three years of deployment (see Figure 7).



System Stability
FLO-DAR has advantages that make it particularly well suited for measuring flow in sewers. The inherent stability and accuracy of the technology used to measure velocity and level reduces the need for and the cost of frequent site verifications. Trend data, scatter plots and alarms are available in near real-time for web enabled or DDS flow meters. These tools allow irregularities in the level to velocity relationship to be quickly identified and resolved.
Site verification is a valuable process and strongly recommended for any important flow study. Often site calibration at the beginning and end of the deployment is sufficient for FLO-DAR instrumented sites. The results of the CH2M HILL report on the DDS sites in Lawrence, Kansas that have been in service for 3 years, confirm the long-term stability of the FLO-DAR flow metering system.
Reduced Maintenance
Non-contact sensing eliminates costly service trips requiring confined space entry to scrub sensors as well as the cost of lost data due to sensor fouling (see Figure 8). Periodic maintenance is typically confined to battery replacement. Batteries can be configured to provide power for a one-year period. Web-enabled FLO-DAR’s and DDS sites also eliminate local data retrieval thereby eliminating most site visits altogether. Because maintenance and battery replacement are included in the service, collection systems or applications utilizing DDS will never need to plan or budget for these expenses.
FLO-DAR has all the benefits of a non-contact flow meter up until surcharge conditions exist. Fouling can occur during these events if debris remains on the sensor as the surcharge recedes. Although fouling is extremely rare, it is readily identified after a surcharge event. If clearing of sensor debris is ever required, it usually can be accomplished at street level without the requirement for confined space entry. There are metering sites where FLO-DAR sensors have been in continuous service for eight years without requiring any maintenance.

Reduced Confined Space Entry
FLO-DAR users realize a drastic reduction in confined space entry due to the elimination of sensor maintenance. Field crews are not required to be sent out to enter manholes to scrub fouled sensors. There are also other confined space entry reductions realized in temporary metering applications where meters are frequently rotated within the collection system. When previously installed FLO-DAR mounting frames are left in place, sensor re-installation can quickly be accomplished with a sensor retrieval tool. Often this can be done from street level without the need for confined space entry (see Figure 9). This is particularly useful when a site is monitored both before and after remediation. There have been custom mounts fabricated by users faced with particularly dangerous manhole atmospheres. These mounts suspend FLO-DAR from the top of the manhole and require no confined space entry. For DDS customers, installation and maintenance are included as part of the service.

Installation
Field crews appreciate the ease in which FLO-DAR is installed in a sewer. Even though a crew member is required to enter a confined space, the FLO-DAR mounting frame is installed above the crown of the pipe. This mounting arrangement typically eliminates the need for a crewmember to wade in the flowing sewage while forcing a band into the pipe. FLO-DAR also reduces safety issues related to the suspension of a crewmember in the flow conduit below the crown of the pipe.
Permanent and temporary devices are available for mounting the FLO-DAR sensor. Permanent mounts are made of stainless steel and designed for long-term use in the rugged sewer manhole environment. The sensor mount attaches to the manhole wall with two 3/8″ expansion bolts (see Figure 10). Temporary mounts consist of a tension jack bar designed to be easily installed, removed and reinstalled for portable flow monitoring applications without the need for drilling (see Figure 11).


Flexibility
Because FLO-DAR operates above the flow stream, it will work in difficult applications where other technologies may not. Low level high velocity flow and chemically active flow are two examples. For example, flow rate in a highly sloped pipe with 0.25″ (6mm) depth flowing 4 ft/s (1.22 m/s) is accurately measured by FLO-DAR. Submerged style sensors installed on a band will create a hydraulic disturbance, (rooster tail), rendering inaccurate flow measurements in these same conditions. In addition, measuring chemically active flow is possible with FLO-DAR. There is no sensor or sensor cable in the flow that can be attacked by high or low pH. The application shown has a pH of 2 (see Figure 12).

Reduced Calibration Verification
FLO-DAR installations operate continually, accurately and reliably over long periods of time. This is facilitated by the inherent advantages of non-contact measurement and drift free Doppler technology. Costly site visits are drastically reduced by eliminating fouling issues and the need to perform routine site calibration verifications. The CH2M HILL Lawrence, Kansas Long-Term Flow Monitor Profiling study confirms FLO-DAR maintains its original calibration after three years of operation.
Data Delivery Service
An accurate, reliable, non-contact flow meter makes Hach’s Data Delivery Service possible. DDS is a unique approach to sewer flow metering that provides a service that allows municipalities to pay only for the flow data they need. Secure flow data is transmitted from web-enabled FLO-DAR sensors and unedited flow data is available 24/7 via the Internet to the offices of city managers and consulting engineers. DDS allows users to take advantage of the non-contact, low maintenance features of FLO-DAR that enable quality data to be made available at low cost. The proven stability of FLO-DAR confirms that frequent periodic maintenance requirements often written into flow monitoring specifications only add cost to the data collection effort. Additionally, alerts can be automatically sent to pagers, phones and e-mail. All of the benefits of FLO-DAR are available with DDS without the capital expense of flow meter purchase (see Figure 13).

Conclusion
Collection systems or applications utilizing DDS obtain reliable flow data for a fixed monthly cost. Maintenance is included in this cost and there is a 95% uptime guarantee or the service is free for that period of time. It is the non-fouling nature of FLO-DAR that allows the DDS concept to be practical and very cost-efficient. The stability and drift-free technology designed into FLO-DAR and its ability to monitor real-time trends and scatter graphs, make frequent site verifications unnecessary. FLO-DAR calibration stability is confirmed by independent engineering studies. The Lawrence, Kansas Long-Term Flow Monitor Profiling study concludes, “Considering the extended flow monitoring duration (exceeding three years), the City of Lawrence long-term flow monitors have performed within the expected range of ±5% on average.” It takes a non-contact flow meter to eliminate sensor fouling and the high cost of associated maintenance and frequent site calibration verification. Only a flow metering device with the accuracy, reliability and non-fouling qualities of FLO-DAR can supply the data guarantee and affordability DDS offers.
References
Dan Hegwald, CH2M Hill, “Lawrence, Kansas Long-Term Flow Monitor Profiling Study”, October 2009
Kevin Krajewski, P.E., V&A (February 2009) “EBMUD Flow Monitoring Technologies Evaluation Study Presentation”, BACWA Collection Systems Committee Meeting, February 2009
James B. Nystrom, Alden Research Laboratory, Inc. Certified Report (July 2003) “Tests of Open Channel Flow Meters in 36″ Pipe (ARL No. 160B-03/C780)