| Accessories |
- Sensor insertion tool
- Extension to hardware clearance
- Additional sensor cable up to 475 (500 max for model 395 and 200 max for model 394)
|
| Accuracy |
AC or DC power: 1% of measured value 0.006 ft/s (0.0018 m/s)
Battery power: 1% of measured value 0.006 ft/s (0.0018 m/s)
Reverse flow: 1% of measured value 0.006 ft/s (0.0018 m/s)
|
| Body material |
Fusion bonded epoxy (NSF 61 approved) coated 316 stainless steel
|
| Certifications |
Standard model:
- ISO 9001:2015 certified quality management system
- NSF/ANSI/CAN 61 & NSF/ANSI 372
- Certified by MET to UL 61010-1
HL model:
- ISO 9001:2015 certified quality management system
- NSF/ANSI/CAN 61 & NSF/ANSI 372
- Certified by MET to UL 61010-1 and MET C22.2 No. 61010-1-04
- Class I, Division 2, Groups A-D, T5
- Class I, Zone 2, IIC T5
|
| Converter |
ProComm GO transmitter
|
| Directional Response |
Directional / Bidirectional
Direction Measurement:
- 395 sensor: Forward flow measurement and reverse flow indication
- 394 sensor: Bidirectional flow measurement
|
| Electrical Connections |
- Quick Connect
- Compression gland seals
|
| Electrode |
316 Stainless Steel
|
| IP Rating |
Standard model: Quick Connect (IP68), Compression gland seals (IP68)
HL model: Quick Connect (IP67), Compression gland seals (IP67)
|
| Linearity |
0.3 % of Range
|
| Line size |
Up to 130″
|
| Measurement Method |
Volumetric flow in filled flow conduits 4” (100 mm) to 138” (3,500 mm) utilizing insertable electromagnetic averaging sensor. Flow indication in English Standard or Metric units.
|
| Mounting |
Converter: Remote mount
|
| Operating Conditions |
Standard Model 10 to 60 °C (14 to 140 °F) up to 250 PSI
HT (High Temperature) option -10 to 93°C (14 to 200°F) up to 250 PSI
|
| Options |
- Hastelloy electrodes
- Annual verification / calibration
- Stainless steel ID tag
|
| Power |
ProComm GO transmitter can use AC power, DC power, and battery
|
| Repeatability |
0.2% of reading
|
| Requirements |
Pipe run requirements for the FPI Mag 3000 sensor can vary, depending on the disturbances in the pipe run. See FPI Mag 3000 manual 30126-03, step 3 of the installation procedure for a table of upstream and downstream straight-pipe run recommendations.
|
| Seal material |
316 Stainless Steel
|
| Sensor Cable |
Standard: 25’/7.6 m McCrometer supplied submersible cable with each remote mount unit.
Optional: Up to 500’/152.4 m, or 25’/7.6 m max for battery powered.
Quick connect: Available in standard cable lengths:
- Feet: 25, 50, 75, 100, 125, 150, 175, 200, 500
- Meters: 7.6, 15.25. 22.5, 30.5, 38.1, 45.75, 53.3, 61, 152.4
Custom cable lengths at additional cost.
|
| Sensor Immersion Depth |
- With standard quick connect: 1.8 m (6 ft.)
- With optional strain relief cable: 9 m (30 ft.)
|
| Storage Conditions |
-15 to 60°C (5 to 140 °F), -15 to 93°C (5 to 200° F) for High Temperature Option
Note regarding storage: During freezing conditions and when meter is not in use, sensor must be removed from pipe and stored in dry conditions.
Note: Damage to the sensor caused by allowing the sensor freeze in the pipe is not covered by the warranty.
|
| Velocity Measurement Range |
See FPI Mag Specification Sheet, 30126-01, for flow meter pipe sizes and flow ranges with ProComm GO transmitter
|
| Warranty |
24 months
|